Executive summary
The live site repeatedly states that Flame Stop II “provides” Centennial Woods products with a “Class A Fire Rating.” This wording appears in the purchasable add-on data on 20 products, PDPs, contractor/exterior pages, fireplace and patio content, a fireproofing article, templates, product JSON, and Product JSON-LD.
The supplied test background does not support that breadth. ASTM reports apply only to the specimens tested and do not establish certification, listing, labeling, ongoing manufacturing inspection, finished-production equivalence, code compliance, exterior/WUI suitability, or safe heat-source clearances. No public DRI-One, ASTM E84, ASTM E2768, FSI/SDI, WUI, ignition-resistant, listed, or labeled claim/report was found in the accessible sources. That absence is positive; the unqualified Class A copy remains the material risk.
Audit evidence and limits
- Shopify Admin: 54 products, 25 collections, 57 pages, 86 articles.
- Published theme: Centennial Woods Live MAIN, theme ID 161720303857; 765 files read across all pages; processing=false.
- Public crawl: sitemap plus direct reads of all Admin product, collection, and page handles; product JSON endpoints; visible text, metadata, image alt/title, linked PDFs, and JSON-LD.
- Local PDF/collateral scan: no target fire-performance terms or ASTM report found.
- Google Drive, email, proposal, marketplace, and authenticated dealer systems were not connected; those require a separate access-enabled pass.
Complete findings table
| ID / source | Exact statement | Product/application | Risk | Replacement/action | Priority | Purchase flow? / duplicate |
|---|---|---|---|---|---|---|
| F1. Product metafield custom_fields.add_ons on 20 products: Cody, Laramie, Sundance White, Saratoga, Cheyenne, Sundance Red, Wheatland, Casper, eight bulk paneling records, and two ready-to-install/rip trim records | “Fire Retardant: Provides Class A Fire Rating.” | Flame Stop II add-on across planks, bulk paneling, trim; profiles/finishes vary | Direct unsupported rating; improper test extension | Use the supplied default replacement: optional factory-applied treatment intended to reduce surface flame spread; not noncombustible, listed, labeled, or code-approved; consult design professional/AHJ | IMMEDIATE | Yes; duplicated in PDPs, JSON-LD, templates |
| F2. Public PDPs, e.g. https://www.centennialwoods.com/products/cody-reclaimed-wood-planks-1 and /products/saratoga-reclaimed-wood-planks | “Flame Stop II Fire Retardant: Provides Class A Fire Rating. $47.00/box …” | Add-on beside price and Add to cart | Direct claim at purchase decision point | Short selector copy: “Optional fire-retardant treatment. Intended to reduce surface flame spread; does not make wood noncombustible, listed, labeled, or code-approved. Confirm suitability with your design professional/AHJ.” | IMMEDIATE | Yes; same source as F1 |
| F3. https://www.centennialwoods.com/products/flame-stop-ii and related handles flame-stop-ii-1, flame-stop-ii-trim, flame-stop-ii-ready-to-rip | Body effectively empty; title “Flame Stop II”; quantity labels “sq ft of Flame Stop,” “sqft flame stopped,” “sq ft of Flame Stop” | Chemical/application-service SKU, not identified tested specimen or finished product | Ambiguous identity | Add only after technical/legal approval: chemical vs Centennial application service vs tested specimen vs production product; chemical-manufacturer reports are not proof of Centennial finished-product performance | HIGH | Yes; name duplicated in add-ons/cart |
| F4. https://www.centennialwoods.com/pages/contractor-professionals; template page.contractor-professionals-v2.json | “Flame Stop II is a fire retardant sealant that provides Centennial Woods products with a Class-A Fire Rating. We recommend adding FlameStop II to any wood that will be installed near fireplaces.” | Contractor/professional; wood near fireplaces | Unsupported rating; unsafe heat-source/clearance implication | Remove fireplace recommendation. Add: treatment does not establish safe clearance; follow appliance instructions, code, and AHJ | IMMEDIATE | Project conversion; duplicated in exterior pages |
| F5. https://www.centennialwoods.com/pages/siding, /pages/shiplap-siding, /pages/reclaimed-lumber, /pages/weather-wood-nominal-1x6 | “Flame Stop II is a fire retardant sealant that provides Centennial Woods products with a Class-A Fire Rating.” | Exterior siding, bulk lumber, shiplap, nominal 1x6 | Exterior/WUI/code implication; extension across profiles/assemblies | “Optional treatment may be available for selected profiles. Do not assume exterior, WUI, ignition-resistant, assembly, or code performance. Confirm the exact profile, treatment, assembly, exposure, and AHJ requirements.” | IMMEDIATE | Project/quote flow; duplicated |
| F6. https://www.centennialwoods.com/pages/reclaimed-wood-siding-v2; template page.reclaimed-wood-siding-v2.json | “...Class-A Fire Rating and fire-resistant performance... near fireplaces or in areas where safety codes require enhanced protection against high temperatures.” | Exterior/interior siding | Unsupported rating; code and high-temperature implication | Delete Class A, fire-resistant performance, fireplace, and safety-code language; use F5 limitation plus clearance warning | IMMEDIATE | Pro page; duplicated in local live2.html |
| F7. https://www.centennialwoods.com/collections/reclaimed-wood-fireplace-mantel | “Our wood always has the option for our Flame Stop II treatment, which provides a Class A Fire Rating.” | Fireplace mantel/surround | Heat-source/clearance implication; unsupported rating | “Wood mantels and surrounds are combustible. Do not use treatment language to determine clearance or suitability. Follow fireplace instructions, code, and AHJ/design-professional direction.” | IMMEDIATE | Collection-to-product flow; search-indexed |
| F8. https://www.centennialwoods.com/blogs/news/how-to-waterproof-and-fireproof-wood | “HOW TO WATERPROOF & FIREPROOF WOOD”; “A Class A fire rating ... will give you peace of mind”; “Flame Stop II (fireproofing)”; “...fireplaces... regions prone to wildfires”; “Keep your home protected ... Class A fire rating!” | Homeowner education, fireplaces, wildfire-prone areas | Fireproof overstatement; WUI/heat-source implication | Retitle “How Fire-Retardant Treatments Affect Wood Surface Flame Spread”; remove fireproof/protected/wildfire/fireplace/Class A language; use default replacement | IMMEDIATE | Content-to-commerce; JSON-LD headline/description |
| F9. https://www.centennialwoods.com/blogs/news/house-siding-options | “A good solution for this is Centennial Woods’ A-rated flame retardant, Flame Stop II.” | Exterior siding/fire-prone areas/insurance | Unsupported rating; insurance and exterior/WUI implication | Treatment is not a substitute for exterior assembly evaluation, WUI/ignition requirement, insurance determination, or code approval | IMMEDIATE | Content flow |
| F10. https://www.centennialwoods.com/blogs/news/exploring-different-types-of-siding-for-a-home | “Optional treatments like Flame Stop II (for a Class A fire rating) ... help this reclaimed natural wood perform well in harsh weather conditions.” | Exterior siding | Improper extension; exterior performance | Say treatment may reduce surface flame spread only under applicable documentation; no exterior/weather/WUI/assembly/code inference | IMMEDIATE | Content flow |
| F11. https://www.centennialwoods.com/blogs/news/patio-wall-ideas | “...a fire-retardant treatment with a Class A rating keeps the installation safe”; “Near a fire pit or outdoor fireplace, add a fire-retardant sealant”; “...Class A fire rating for installations near fire features.” | Patio wall, fire pit, outdoor fireplace/kitchen | Unsafe heat-source; exterior/WUI/code implication | Remove treatment-as-safety language. Defer to heat-source manufacturer, required clearances, code, design professional, and AHJ | IMMEDIATE | Content flow; three repeats |
| F12. https://www.centennialwoods.com/blogs/news/how-to-install-wood-siding | “Check ... building codes ... fire ratings”; “Add a flame-retardant coating for added fire protection...” | Exterior siding | Ambiguous code implication | “Check local requirements; do not assume optional treatment satisfies fire-rating, WUI, ignition, or assembly requirements.” | HIGH | Content flow |
| F13. https://www.centennialwoods.com/blogs/news/shiplap-vs-tongue-and-groove-siding | “In fire-prone areas, a flame-retardant coating adds protection for either choice.” | Shiplap/tongue-and-groove exterior | Exterior/WUI implication | Treatment is not a substitute for profile-specific exterior/WUI/assembly documentation or AHJ approval | HIGH | Content flow |
| F14. https://www.centennialwoods.com/blogs/news/types-of-wood-finishes | “...protective sealants to prevent fire and moisture damage.” | General finishes | “Prevent fire damage” overstatement | “Optional moisture and fire-retardant treatments; treatment is intended to reduce surface flame spread and does not prevent fire damage.” | HIGH | No direct cart |
| F15. https://www.centennialwoods.com/blogs/news/vinyl-siding-vs-wood-siding | “Flame Stop II ... shields against fire damage. These treatments enhance the durability and safety of our wood siding...” | Exterior siding comparison | Exterior safety implication | Treatment may alter surface flame-spread behavior under documented conditions; no overall siding safety/WUI/code inference | HIGH | Content flow |
| F16. Fireplace inspiration: contemporary-uses-for-reclaimed-wood, 15-reclaimed-wood-design-ideas, six-ways-to-utilize-shiplap, reclaimed-wood-on-netflixs-instant-dream-home, reclaimed-wood-mantel-ideas, mid-century-wood-paneling-design-guide, and Cheyenne PDP | Fireplace surrounds/mantels are shown or described without combustible-material/clearance warning | Fireplace surrounds/mantels | Ambiguous but potentially unsafe when paired with F4/F7 | Add: “Design imagery is not installation guidance. Wood is combustible; maintain required clearances and follow appliance, code, and AHJ requirements.” | HIGH | Some PDP/collection; repeated library pattern |
| F17. Product HTML/JSON/JSON-LD for Saratoga, Wheatland, Cheyenne, Sundance White/Red, Cody, Laramie and trim | Source add-on content carries the rating claim into Product JSON-LD descriptions | Search/merchant representation | Structured-data/feed duplication | Correct source content, then verify JSON-LD/product feeds; do not patch visible HTML only | IMMEDIATE | Yes; duplicate F1/F2 |
| F18. Theme config/settings_data.json and cart/footer | “Orders with Centennial Seal or Flame Stop II will take an additional 7-21 business days to arrive.” | Logistics | Acceptable factual lead-time statement; insufficient limitation disclosure | Retain as logistics copy; link treatment limitation at selector | LOW | Yes; repeated theme/cart/footer |
| F19. MAIN templates page.contractor-professionals-v2.json, page.reclaimed-wood-siding-v2.json, page.reclaimed.json, page.centennial-lab.json; local live2.html | “Can be Purchased with Pre-Applied Protective Sealant and/or Fire Retardant Sealant”; “UV / Moisture Sealant & Fire Retardant Available.” | Exterior/interior product cards | Acceptable availability only if qualified; misleading beside exterior/durability claims | Append that availability does not establish rating, listing, label, code, exterior/WUI performance, or safe clearance | HIGH | Pro/project flow; four templates |
| F20. External Material Bank: https://www.materialbank.com/partner/centennialwoods | “Planks are suitable for commercial and residential projects... interior and exterior uses... moisture proof Centennial Seal and a Class A fire retardant called Flamestop II.” | Distributor/specifier listing | External commercial/exterior/Class A implication | Request treatment-only, specimen-limited language; remove “moisture proof” and Class A unless approved current listing/label exists | IMMEDIATE | Yes—specifier discovery |
| F21. External resellers: mymaterialwarehouse.com, rdrtechnologies.com, valuebuildingsupply.com | Reseller pages describe Flame Stop II as suitable for exterior wood, “non-combustible,” or Class A | Chemical product, not necessarily Centennial finished product | Chemical claims may be mistaken for Centennial claims | Do not quote reseller/chemical claims as Centennial finished-product performance; management/legal decide notices | HIGH | Indirect/project sales |
Negative findings
No accessible hit for DRI-One, ASTM E84, ASTM E2768, WUI, ignition resistant, or FSI/SDI was found. No ASTM or DRI-One report was found in accessible local PDFs. No direct fire-rating text was found in audited public image alt/title attributes. The fireproof article’s infographic alt text should still be visually reviewed. GREENGUARD/FSC “certified” references are environmental/indoor-air claims, not fire certification.
Immediate checkout and sales-flow corrections
- Replace the add-on wording in custom_fields.add_ons across all 20 products.
- Add limitations at the treatment selector and document the chemical/service/specimen/production distinction.
- Review the four Flame Stop II SKU bodies and quantity labels.
- Verify PDP HTML, cart, product JSON, Product JSON-LD, product feeds, and marketplace exports after source correction.
- Remove treatment-as-safety language for fireplaces, stoves, grills, fire pits, chimineas, high-temperature areas, and “safety codes.”
- Add combustible-material/clearance warnings to fireplace, mantel, and surround content.
- Hold Class A, A-rated, fireproof, prevents fire damage, WUI, ignition resistant, and code-compliant language pending approval.
Management/legal/technical review
Approve or reject: any Class A wording and its exact profile/finish/thickness boundary; Flame Stop II vs DRI-One naming; publication of any E84 result and exact specimen/test limitations; disclosure of the E2768 failure if E84 is referenced; any production inspection/listing/labeling evidence; exterior/WUI/ignition/decking/siding/fireplace/stove/grill/fire-pit/chiminea suitability; combined “certified/safe/commercial” impressions; and external dealer corrections.
External correction list
Material Bank is the identified Centennial-branded distributor/specifier correction. Reseller pages for Material Warehouse, RDR Technologies, and Value Building Supply need management/legal review where Centennial is named or linked. Authenticated marketplace/dealer inventory remains open because those systems were not connected.
Post-publish verification
- Re-crawl all 20 PDPs, treatment SKUs, contractor/siding/lumber/fireplace/patio pages, blogs, FAQs, and resources.
- Check visible copy, titles, meta descriptions, Open Graph, JSON-LD, image alt/captions, PDFs, feeds, cart, checkout-adjacent text, and search snippets.
- Confirm no unsupported rating, listing, label, certification, WUI, ignition, exterior-fire, clearance, or code claim remains.
- For any retained ASTM reference, identify exact specimen, thickness, finish, substrate/self-supporting condition, FSI/SDI, report date/lab, and limitations; state it is not certification, listing, labeling, or code approval.
- Search quote/proposal/order-confirmation/sales-email/presentation/internal-script systems once access is available.
- Record URLs, source fields, exact before/after copy, duplicate count, timestamp, and fresh public read-back.